Definitions
- Bollard Crash Barrier
- Natural Surveillance Create height advantage and secure perimeter
- Guard in common access areas and lobbies
- Issues selectin a site
- Is it visible
- Distance to emergency services
- Accessibility
- Regional natural desasters
Indoor
- Drop Ceilings could give access to secure rooms
- Wireing closets at should be at secure locations
- Electromagnetic interference (EMI) , also called radio-frequency interference (RFI) when in the radio frequency spectrum, is a disturbance generated by an external source that affects an electrical circuit by electromagnetic induction, electrostatic coupling, or conduction.
Electricity
- Voltage spike are fast, short duration electrical transients in voltage (voltage spikes), current (current spikes), or transferred energy (energy spikes) in an electrical circuit.
- Brownout is an intentional or unintentional drop in voltage in an electrical power supply system. Intentional brownouts are used for load reduction in an emergency.
Liquids
- Have drains with positive pressure
Air
- Overpressure in Datacenters and access doors
- Hydrometer Between (40% - 60% is OK)
- Thermometer (20° bis 22°)
-
Fire
- Prevention
- Detection
- Surpression
- Plenum cable is electrical cable that is laid in the plenum spaces of buildings
- Halon is a liquefied, compressed gas that stops the spread of fire by chemically
- A wet pipe sprinkler system is a sprinkler system employing automatic sprinkler heads attached to a piping system containing water and connected to a water
- A dry pipe sprinkler system is a sprinkler system employing automatic sprinkler heads attached to a piping system but not filled with water at the start
- A Preaction sprinkler system is a sprinkler system employing automatic sprinkler heads attached to a piping system filled with pressurized air
- A deluge fire sprinkler system is similar to a pre-action system except the sprinkler heads are open and the pipe is not pressurized with air. Deluge systems are connected to a water supply through a deluge valve that is opened by the operation of a smoke or heat detection system.
Locks
- Locks
- Cypher Locks
- Device Locks
- Piggybacking Two people entering with the same card
Fencing
Lighting
- No Island of lighting. Total coverage of light prefered
- Point Light Outward so guards are not blinded
Cameras
- Fixed Focal lens
- Varied focal lens
- Depth of field
- Iris, manual or automatic
- Acoustic monitoring
- Smoke detction
- Electrical monitoring
- Temperature monitoring