Definitions

  • Bollard Crash Barrier
  • Natural Surveillance Create height advantage and secure perimeter
  • Guard in common access areas and lobbies
  • Issues selectin a site
    • Is it visible
    • Distance to emergency services
    • Accessibility
    • Regional natural desasters

Indoor

  • Drop Ceilings could give access to secure rooms
  • Wireing closets at should be at secure locations
  • Electromagnetic interference (EMI) , also called radio-frequency interference (RFI) when in the radio frequency spectrum, is a disturbance generated by an external source that affects an electrical circuit by electromagnetic induction, electrostatic coupling, or conduction.

Electricity

  • Voltage spike are fast, short duration electrical transients in voltage (voltage spikes), current (current spikes), or transferred energy (energy spikes) in an electrical circuit.
  • Brownout is an intentional or unintentional drop in voltage in an electrical power supply system. Intentional brownouts are used for load reduction in an emergency.

Liquids

  • Have drains with positive pressure

Air

  • Overpressure in Datacenters and access doors
  • Hydrometer Between (40% - 60% is OK)
  • Thermometer (20° bis 22°)

Fire

  • Prevention
  • Detection
  • Surpression

  • Plenum cable is electrical cable that is laid in the plenum spaces of buildings
  • Halon is a liquefied, compressed gas that stops the spread of fire by chemically
  • A wet pipe sprinkler system is a sprinkler system employing automatic sprinkler heads attached to a piping system containing water and connected to a water
  • A dry pipe sprinkler system is a sprinkler system employing automatic sprinkler heads attached to a piping system but not filled with water at the start
  • A Preaction sprinkler system is a sprinkler system employing automatic sprinkler heads attached to a piping system filled with pressurized air
  • A deluge fire sprinkler system is similar to a pre-action system except the sprinkler heads are open and the pipe is not pressurized with air. Deluge systems are connected to a water supply through a deluge valve that is opened by the operation of a smoke or heat detection system.

Locks

  • Locks
  • Cypher Locks
  • Device Locks
  • Piggybacking Two people entering with the same card

Fencing

Lighting

  • No Island of lighting. Total coverage of light prefered
  • Point Light Outward so guards are not blinded

Cameras

  • Fixed Focal lens
  • Varied focal lens
  • Depth of field
  • Iris, manual or automatic
  • Acoustic monitoring
  • Smoke detction
  • Electrical monitoring
  • Temperature monitoring